Comparison of Platelets with Anticoagulant K2EDTA

Syuhada Syuhada, Abdurrohman Izzuddin, Hendri Yudhistira

  • Syuhada Syuhada Universitas Malahayati
  • Abdurrohman Izzuddin Universitas Malahayti
  • Hendri Yudhistira Universitas Malahayati
Keywords: Hematology examination, K2EDTA, Blood volume

Abstract

Introduction: difficulty in taking patient blood samples often occurs in obese patients, newborns, and blood sampling in patients with small veins also causes insufficient blood volume collection. Objective: to determine whether there is a difference between the results of the platelet hematology examination in the blood sample volume of 3 mL, 2 mL, and 1 mL with the anticoagulant K2EDTA. Methods: This study used an observational analytic method with a cross-sectional design. calculate. Results: The mean number of platelets in the blood volume of 2 mL and 3 mL in the vacutainer tube was higher than that of the 1 mL blood sample. Conclusion: There is no significant difference in the results of the comparison of platelet counts between blood volumes of 1 mL, 2 mL, and 3 mL in the K2EDTA vacutainer tube

Downloads

Download data is not yet available.

Author Biographies

Syuhada Syuhada, Universitas Malahayati

Departemen Patologi Klinik, Fakultas Kedokteran

Abdurrohman Izzuddin, Universitas Malahayti

Departemen Anatomi, Fakultas Kedokteran

Hendri Yudhistira, Universitas Malahayati

Fakultas Kedokteran

References

Apriliani, T. (2016). Gambaran hitung jumlah trombosit dengan antikoagulan K3EDTA 10% volume 5, 10 dan 15 µl.

De la Salle, B. (2019). Pre‐and postanalytical errors in haematology. International journal of laboratory hematology, 41, 170-176. DOI: 10.1111/ijlh.13007.

Deviani, S. (2017). Perbedaan Variasi Volume Darah Dalam Tabung Vacutainer EDTA Terhadap Jumlah Trombosit (Doctoral dissertation, Universitas Muhammadiyah Semarang).

Gandasoebrata, R. (2013). Penuntun laboratorium Klinik. cetakan keenambelas. Jakarta: Dian Rakyat.

Hall, J. E., & Hall, M. E. (2018). Guyton and Hall textbook of medical physiology e-Book. Elsevier Health Sciences.

Kemenkes RI. (2015). Peraturan Menteri Kesehatan Republik Indonesia Nomor 91 Tahun 2015 tentang Standar Pelayanan Transfusi Darah. Berita Negara Republik Indonesia Tahun 2016 Nomor 36. Jakarta

Kuman, M. (2019). Perbedaan Jumlah Eritrosit, Leukosit Dan Trombosit Pada Pemberian Antikoagulan Konvensional dan EDTA Vacutainer. (Doctoral dissertation, Poltekkes Kemenkes Kupang).

Arviananta, R., Syuhada, S., & Aditya, A. (2020). The difference in the number of erythrocytes between fresh and stored blood. Jurnal Ilmiah Kesehatan Sandi Husada, 9(2 SE-Articles). https://doi.org/10.35816/jiskh.v12i2.388

Khasanah, U. (2016). Perbedaan Hasil Pemeriksaan Hitung Jumlah Trombosit Pada Darah Vena Dan Darah Kapiler Dengan Metode Tabung. Skripsi.

Syuhada, S., Aditya, A., & Candrawijaya, I. (2020). Difference between Hematocrit of Fresh Blood and Save Blood (30 Days). Jurnal Ilmiah Kesehatan Sandi Husada, 9(2 SE-Articles). https://doi.org/10.35816/jiskh.v12i2.379

Yusmaidi, Y., Rafie, R., Nur, M., & Nabilah, B. (2020). Derajat Toksisitas Trombosit pada Penderita Kanker Kolorektal yang Mendapat Kemoterapi CapeOX. Jurnal Ilmiah Kesehatan Sandi Husada, 11(1), 313–320.

Lippi, G., Von Meyer, A., Cadamuro, J., & Simundic, A. M. (2019). Blood sample quality. Diagnosis, 6(1), 25-31.

Marpiah, S. (2017). Pengaruh Penundaan Darah K3EDTA Terhadap Jumlah Trombosit Metode Automatic Hematology Analyzer (Doctoral dissertation, Universitas Muhammadiyah Semarang).

Marson, F. A. (2018). Perbedaan Teknik Pemasangan Tourniquet Terhadap Kadar Kalium Serum. Jurnal Kesehatan, 11(2), 91-98.

Mengko, R. (2013). Instrumen Laboratorium Klinik.

Narula, A., Yadav, S. K., Jahan, A., Verma, A., Katyal, A., Anand, P., ... & Singh, S. (2019). Pre-analytical error in a hematology laboratory: an avoidable cause of compromised quality in reporting. Clinical Chemistry and Laboratory Medicine (CCLM), 57(10), e262-e264.

Nugraha, G. (2015). Panduan Pemeriksaan Laboratorium Hematologi Dasar. CV Trans Info Medika. Jakarta.

Nurrachmat, H. (2005). Perbedaan Jumlah Eritrosit, Leukosit Dan Trombosit Pada Pemberian Antikoagulan Edta Konvensional Dengan Edta Vacutainer (Doctoral dissertation, Program Pascasarjana Universitas Diponegoro).

Radheya, I. P. (2018). Pengaruh Variasi Volume Darah Pada Tabung Vacutainer Tripotassium Ethylenediaminetetraacetate (K3EDTA) Terhadap Jumlah Trombosit (Doctoral dissertation, Jurusan Analis Kesehatan).

Riswanto, (2013). Pemeriksaan Laboratorium Hematologi. (Yogyakarta: Alfamedika dan Kanal Medika).

Sherwood, L. (2020). Fisiologi manusia dari sel ke sistem.

Sujud, dkk. (2015). Perbedaan Jumlah Trombosit Pada Daerah EDTA yang Segera Diperiksa dan Penundaan Selama 1 Jam Di Laboratorium RSJ Grhasia, Yogyakarta.

Sysmex. (2014). Automated Hematology Analyzer XP series XP-100 Instruction for Use. (Kobe: Sysmex Corporation).

Xu, M., Robbe, V. A., Jack, R. M., & Rutledge, J. C. (2010). Under‐filled blood collection tubes containing K2EDTA as anticoagulants are acceptable for automated complete blood counts, white blood cell differential, and reticulocyte count. International journal of laboratory hematology, 32(5), 491-497.

Published
2021-06-30
How to Cite
Syuhada, S., Izzuddin, A., & Yudhistira, H. (2021). Comparison of Platelets with Anticoagulant K2EDTA. Jurnal Ilmiah Kesehatan Sandi Husada, 10(1), 170-176. https://doi.org/10.35816/jiskh.v10i1.575

Most read articles by the same author(s)

Obs.: This plugin requires at least one statistics/report plugin to be enabled. If your statistics plugins provide more than one metric then please also select a main metric on the admin's site settings page and/or on the journal manager's settings pages.