Isolation and Identification of Escherichia Coli Bacteria Causes Waterborne Disease in Bottled and Refilled Water

Gusti Rizka Khairunnida, Hetti Rusmini, Esteria Maharyuni, Efrida Warganegara

  • Gusti Rizka Khairunnida Universitas Malahayati
  • Hetti Rusmini Universitas Malahayati
  • Esteria Maharyuni Universitas Malahayati
  • Efrida Warganegara Universitas Lampung
Keywords: Escherichia coli, Waterborne disease, Drinking water

Abstract

Abstract. Background : Refilled water drinking store and packaged water drinking often can be found in cities with a high demand of water by the community, whether it’s drinking water or for daily basis. Contaminated water if being consumed, will cause a disease. Purpose : To know contamination of Escherichia coli bacteria cause of waterborne disease on refilled drinking water and packaged drinking water in Kelurahan Kemiling Raya by filtering method and isolate and identified on differential selective media. Method : Descriptive research design with experimental qualitative approach. Sample of refilled drinking water sample and packaged water drinking are filtered with a membrane filter and incubated on differential selective media Chromogenic Coliform Agar to know whether there is a contamination of Escherichia coli cause of waterborne disease. Result : There are Escherichia coli bacteria cause waterborne disease colonies in refilled drinking  water on sample X, Y, and Z with each having 2,4 x 102 cfu/100ml, 6,8 x 102 cfu/100ml and sample Z having categorized by TBUD because of too much colonies, but on sample W there isn’t any. On packaged drinking water sample A and B both have the same number of colonies Escherichia coli which 2,0 x 100 cfu/250ml. Conclusion : The number of Escherichia coli bacteria on refilled drinking water is greater than packaged drinking water. There isn’t any Escherichia coli bacteria cause of waterborne disease in refilled drinking water whom uses reserved osmosis technology.

Downloads

Download data is not yet available.

Author Biographies

Gusti Rizka Khairunnida, Universitas Malahayati

Program Studi Kedokteran Fakultas Kedokteran

Hetti Rusmini, Universitas Malahayati

Departemen Farmakologi Fakultas Kedokteran

Esteria Maharyuni, Universitas Malahayati

Departemen  Dokter Umum Fakultas Kedokteran

Efrida Warganegara, Universitas Lampung

Departemen Mikrobiologi Fakultas Kedokteran

References

Afif, Fathoni., dkk. 2015. Identifikasi Bakteri Escherichia Coli pada Air Minum Isi Ulang yang Diproduksi Depot Air Minum Isi Ulang di Kecamatan Padang Selatan. Jurnal Kesehatan Andalas, 4(2).

Afrisetiawati, Rani., dkk. 2016. Identifikasi Bakteri Escherichia coli pada Air Minum Isi Ulang yang Diproduksi DAMIU di Kelurahan Lubuk Buaya Kota Padang. Jurnal Kesehatan Andalas, 5(3).

Athena, dkk. 2005. Pengaruh Pengolahan Air di Depot Air Minum Isi Ulang dalam Menormalkan Derajat Keasaman (pH). Media of Health Research and Development, 15 (2).

Brooks, G.F., dkk. 2012. Jawetz, Melnick, & Adelberg Mikrobiologi Kedokteran Edisi 25. Aliha Bahasa Edi Nugroho dan RF Maulany. Jakarta: EGC.

Forstinus, N. O., dkk. 2016. Water and Waterborne Diseases: A Review. International Journal of TROPICAL DISEASE & Health, 12(4).

Hanifa, Fidati., dkk. 2020. Efektivitas Madu Murni Dan Propolis Terhadap Bakteri Pencemar Susu Penyebab Foodborne Disease pada Produk Susu Kemasan. Jurnal Ilmiah Kesehatan Sandi Husada, 11(1).

Kemendag RI. 2004. Keputusan Mentri Perindustrian dan Perdagangan RI Nomor : 651/MPP/Kep/2004 Tentang Persyaratan Teknis Depot Air Minum da Perdagangannya. Jakarta: Kemenenterian Perindustrian dan Perdagangan RI.

Kemenkes RI. 2010. Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/Per/IV/2010 Tentang Persyaratan Kualitas Air Minum. Jakarta: Kementerian Kesehatan RI.

Standar Nasional Indonesia. 2009. Tentang Batas Maksimum Cemaran Mikroba dalam Pangan, SNI 7388: 2009. Badan Standardisasi Nasional.

Standar Nasional Indonesia. 2015. Cara Uji Air Minum dalam Kemasan, SNI 3554:2015. Badan Standarisasi Nasional.

Sumantri, A. 2017. Kesehatan Lingkunga, Edisi Ke-4. Depok: Kencana.

Sunarti, R. N. 2015. Uji Kualitas Air Sumur Dengan Menggunakan Metode MPN (Most Probable Numbers). Bioilmi, 1(1).

Staf Pengajar FKUI. 2010. Buku Ajar Mikrobiologi Kedokteran. Jakarta: FKUI.

Widiyanti, N. L., dkk. 2017. Parameter Fisik dan Jumlah Perkiraan Terdekat Coliform Air Danau Buyan Desa Pancasari Kecamatan Sukasada Buleleng. JST (Jurnal Sains Dan Teknologi), 6(1).

Zikra, W., dkk. 2018. Identifikasi Bakteri Escherichia coli (E.coli) pada Air Minum di Rumah Makan dan Cafe di Kelurahan Jati serta Jati Baru Kota Padang. Jurnal Kesehatan Andalas, 7(2).

Published
2020-12-31
How to Cite
Khairunnida, G., Rusmini, H., Maharyuni, E., & Warganegara, E. (2020). Isolation and Identification of Escherichia Coli Bacteria Causes Waterborne Disease in Bottled and Refilled Water. Jurnal Ilmiah Kesehatan Sandi Husada, 9(2), 634-639. https://doi.org/10.35816/jiskh.v12i2.370

Most read articles by the same author(s)

Obs.: This plugin requires at least one statistics/report plugin to be enabled. If your statistics plugins provide more than one metric then please also select a main metric on the admin's site settings page and/or on the journal manager's settings pages.